Appointment
Irrigation hydrant valve is designed for the quick connection of inlet pipe of the pivot with irrigation system hydrant. Irrigation hydrant valve is installed on the pivot inlet hose with the clamps.
Hydrant valves are usually operated by with the irrigation hydrant.
Design and operation principle
Irrigation hydrant valve consists of the body 1, which is fastened to the irrigation hydrant with the help of the hooks 2. Handle 4 installed on the stem 3 puts the screw of the irrigation hydrant in motion therefore enabling the delivery of water into the irrigation system. Sleeve gasket 5 and O-rings seal the hydraulic unit hermetically.
one. |
housing |
structural steel |
2. |
hook |
structural steel |
3. |
stock |
stainless steel |
4. |
a pen |
structural steel |
5. |
cuff |
Rubber mixture |
Dimensions
Index |
Dy, inlet, mm |
Dy, outlet, mm |
A, mm |
H, mm |
L, mm |
КГО Dy-100х4" |
100 |
100 |
315 |
276 |
165 |
КГО Dy-150х6" |
150 |
150 |
335 |
375 |
170 |
КГО Dy-150х8" |
150 |
200 |
425 |
375 |
170 |
Technical specifications
Operating pressure, kgf/cm2 (MPa) |
10 (1.0) |
Test pressure, kgf/cm2 (MPa) |
20 (2.0) |
Coating, SFS EN ISO 12944 |
powder paint |
Weight, kg |
nine |